Description
SPECIFICATIONS
|
ALTAIR io360 Area Gas Monitor |
|||
| Warranty | 4 years
Oxygen Sensor: 2 years Low-energy Combustible: 1 year |
||
| Durability | Drop Test: 10ft (3m)
Ingress Protection: IP68 |
||
| Temperature | Normal Operating: –4° to 131° F (–20° to 55° C)
Extending Operating: –40° to 131° F (–40° to 55° C) Storage: 32 to +95 °F (0 to 35 °C) |
||
| Humidity | Intermittent: 5% – 95%
Non-condensing: 15% – 90% |
||
| Power | Batteries: 3 replaceable lithium thionyl chloride batteries
Runtime: nominally 50-60 days 4-gas, 80-85 days without combustible sensor |
||
| Physical | Weight: 1.6 lb. (0.7 kg)
Dimensions: 5.2” x 5.6” x 2.7” (132 x 142 x 69 mm) |
||
| Alarms | Audible: 90 Db @ 1 ft. (0.3 m)
Visual: RGB LED |
||
| Data Logging | Periodic, Event, Instrument, Calibration logs stored on detector (at least 2 months) and sent to Safety io Grid. | ||
| Range | Up to 1000 ft. (~300 m) line of site HUB to detector 2 mesh hops to extend range. | ||
| Radio | 915 MHz, Bluetooth, RFID | ||
| Sensors |
Gas LEL O₂ CO H₂S |
Range 0-100% 0-30% 0-1999 ppm 0-200 ppm |
Resolution 1% 0.1% 1 ppm 1 ppm |
|
MSA HUB Specifications |
|
| Warranty | 4 years |
| Durability | Ingress Protection IP67 |
| Temperature Range | 4° to 140° F (–20° to +60° C) for hazardous locations |
| Humidity | 10 to 90% relative humidity, non-condensing |
| Power | Nominal: 24 V DC Line power
Range: 6 V to 32 V |
| Physical | Weight: 3 lb. (1.4 kg)
Dimensions: 7.5” x 7.7” x 3.9” (190mm x 195mm x 99mm) |
| Radio | 915 MHz, Bluetooth, Cellular 2G/3G/4G, 2.4 GHz Wi-Fi (a,b,g,n) |
| Ethernet | 10/100 mbit |